Start-up procedures
Checki
ng..
tb,
e,.,
speed.
log
readout
If the speed log is equipped with a test output signal
, this
test can be carried out with the ship ashore, butifnot, this
test must be done while the ship is sailing.
Connect the speed log cable
(1) to the connector marked
PULSE LOG (or PORT B for a serial line
log).
Press the ON/OFF-HOIST button to start up the Sonar
Control Unit.
Check if a big A is displayed on the SPEED line in
the
menu. This A means
that the speed will be
automatically
read from the connected speed log. If not, set the speed to
be read automatically as described in the
SPEED
submenu.
Check if the speed readout corresponds to
the speed log.
If the readout
does not change, or is incorrect
, refer to
chapter 7.3 in section "
Installation procedures
" and check
the following:
- Check
if the switch setting on DIL switch Sl
(and links
for a log with serial line output) on the
CUB PCB is
correct according to the table for the
speed log (see
chapter 7.3 in section "
Installation procedures
If a pulse log is connected
, refer to figure 23 in section
Installation procedures" and the text below the figure
to check the pulse log signal.
- Check
if the termination on the
LOG plug is correct.
- Check
the speed signal at the LOG
plug terminations.
When the speed log readout works OK
, switch off the
Sonar Control Unit by
pressing the
ON/OFF -
HOIST
button.
Checking the echo sounder and trawl system
readout
If such auxiliary equipment is connected to the sonar system
use the test procedure described in the appendix
for the
installation.