Instruction manual
9
857-164777 / A
Serial line configuration and pin allocations
→ Refer to drawing no. 824-108590, ITI Installation manual.
The four serial port (fem ale) connectors are found on the
transceiver unit plug panel, located in the bottom of the cabinet.
The serial lines can be configured electrically as follows:
• Port A can be configured as RS-232 or RS-422.
• Ports B and C are standard RS-232 serial l ines only.
• Port D can be configured as RS-232, RS-422 or current loop.
Table 3 gives an overview of the different ways of configuring the
serial lines electrically, and the dedicated use of each line.
Port
Possible
configurations
ITI port allocation Format
A RS-232 Echo sounder NMEA 0183
B RS-422 - Winch control
- Track pl otter
- Data logger
NMEA 0183
C RS-232 Sonar NMEA 0183
D - RS-232
-- RS-422
-- 20 mA Current loop
Navigator NMEA 0183
Table 3 Possible serial port configurations and allocations
→ Refer to the ITI installation manual for further information
regarding configuration port A and D.
Comentários a estes Manuais