Simrad SP60 - REV D Manual de Instalação

Consulte online ou descarregue Manual de Instalação para não Simrad SP60 - REV D. Simrad SP60 - REV D Installation manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 218
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Installation manual

Simrad SP60Low frequency fishery sonarInstallation manualA L W A Y S A T T H E F O R E F R O N T O F T E C H N O L O G Ywww.simrad.com

Página 2

Simrad SP60VI851-164574 / C8.8 Current meter 84...8.9 Radio buoys 85...

Página 3

Simrad SP6084851-164574 / C8.8 Current meterThe SP60 sonar can read the data from the following current metersystems:• Kaijo DCG-200The interface is b

Página 4

Connecting peripheral equipment85851-164574 / C8.9 Radio buoysThe SP60 sonar can read the data from one of the following GPSbased radio buoy systems:•

Página 5 - Sections

Simrad SP6086851-164574 / C8.10 Trackball / mouse connectionIn addition to the standard operating panel, an extra trackball ormouse with USB interface

Página 6 - Additional copies

Start-up procedures87851-164574 / C9 START-UP PROCEDURES9.1 IntroductionThe procedures in this chapter shall be carried out once all thehardware units

Página 7 - Table of contents

Simrad SP6088851-164574 / C9.2 Check-list before start-up commencesBefore you commence with the start-up procedure, check thefollowing items. To ensur

Página 8

Start-up procedures89851-164574 / C9.3 Starting up the stand-by power supplyIn order to start up the sonar units, the +24 Vdc stand-by powersupply in

Página 9

Simrad SP6090851-164574 / C4 Measure the mains voltage supplied to the Transceiver Unit.- Write down the measured voltage here:Supply voltage (Vac):5

Página 10 - angle 121

Start-up procedures91851-164574 / C9.4 Starting up the Hull UnitIntroductionObserve the following procedure to start up the Hull Unit. Toensure correc

Página 11

Simrad SP6092851-164574 / CS 302K301 K302HAND CRANKS 303(CD3125 / WMF / GIF)S301S302K302S303HandcrankREMOTEHOIST STOPLOWERK301Figure 31 TheMot

Página 12

Start-up procedures93851-164574 / C(CD6243C)Upper limitswitch S304Lower limitswitch S305Motor ControlUnitHoist motorHand crankFigure 32 Location of th

Página 13 - Document revisions

Installation manualVII851-164574 / C9.13 Setting own ship parameters 122...Ship dimensions 122...

Página 14

Simrad SP6094851-164574 / C2 Measure the three-phase voltage on the terminals of themotor overload switch S301 in the motor control unit.- Write down

Página 15 - High voltage safety warning

Start-up procedures95851-164574 / C5 Reinsert the 3-phasemains fuses for the hull unit in the ship’sfusebox.Functional check with powerThe hull unit i

Página 16 - Do you know what to do?

Simrad SP6096851-164574 / C14 Release the motor overload switch S301 by pressing the redbutton marked 0. This will prevent unwanted lowering of thetra

Página 17 - 1INTRODUCTION

Start-up procedures97851-164574 / C9.5 Starting up the Wheelhouse UnitsIntroductionIf the AC mains plug on the SP60 Sonar Processor Unit has beendisco

Página 18 - 1.2 System diagram

Simrad SP6098851-164574 / CDisplay set-upObserve the following procedure to set up the display and retrievesimulated sonar echoes.1 Refer to the instr

Página 19 - Figure 1 SP60 system diagram

Start-up procedures99851-164574 / C9.6 Checking the Operating PanelIntroductionThe simulated echoes makes it possible to test out most of theoperation

Página 20 - 1.3 Scope of supply

Simrad SP60100851-164574 / CSYMBOL(CD5347)Target markerOwn ship markerCircle markerGear symbolFigure 36 The Symbolfield with the threemarkers and the

Página 21

Start-up procedures101851-164574 / Cb Press the Horizontal tab to bring up this menu.c Press the Gain H- and Gain H+ buttons repeatedly (field4 on the

Página 22 - 1.4 Peripheral equipment

Simrad SP60102851-164574 / CObject menu13 Check the Object menu.a Move the cursor to a new position inside the echo area.b Press the Object button (fi

Página 23

Start-up procedures103851-164574 / Cb Check that the white audio line on the screen trainscorrespondingly.c Try both directions.18 Check the Position

Página 24 - 1.5 Supply conditions

Simrad SP60VIII851-164574 / CProblems with flow noise 147...12 TECHNICAL SPECIFICATIONS 150...12

Página 25 - 1.6 General safety rules

Simrad SP60104851-164574 / C9.7 Checking the hoisting/lower systemIntroductionThe following set of procedures requires two persons. One personmust be

Página 26 - 1.7 Installation requirements

Start-up procedures105851-164574 / CChecking the bridge functionsNote This procedure must be performed simultanously with the nextprocedure; Checking

Página 27 - Dry docking

Simrad SP60106851-164574 / Cc When lower position has been reached, check that theLED next to the Down button illuminates continuously,that the audibl

Página 28 - 1.8 Equipment handling

Start-up procedures107851-164574 / Cc When upper position has been reached, check that theLED next to the Up button illuminates continuously, thatthe

Página 29 - Initial preservation

Simrad SP60108851-164574 / CBlank pageThis page is intentionally left blank. It allows you to remove the next test procedure fromthe manual, and bring

Página 30

Start-up procedures109851-164574 / CChecking the sonar room functionsNote This procedure must be performed simultanously with theprocedure and checkli

Página 31 - General unpacking procedure

Simrad SP60110851-164574 / C9.8 StartinguptheTransceiverUnitObserve this test procedure to power up the Transceiver Unit forthe first time.ANALOGPOWER

Página 32 - Transducers

Start-up procedures111851-164574 / C7 Start up the sonar in the wheelhouse by pressing the Powerbutton on the Operating Panel for approximately twosec

Página 33 - 1.9 Storage

Simrad SP60112851-164574 / C9.9 Self-noise testThis test procedure will allow you to check the system’s self-noise.Observe the following procedure to

Página 34 - Cleaning cabinets

Start-up procedures113851-164574 / C9.10 System start-upIntroductionTo do the final tests, the vessel must be in the sea. This is becausethe transduce

Página 35 - Re-packing

Installation manualIX851-164574 / CDocument revisionsRev Date Written by Checked by Approved byA 25.01.02 RBr SØJ SØJB 02.04.02 RBr SØJ SØJC 26.08.03

Página 36 - ESD precautions

Simrad SP60114851-164574 / CStarting up the transmitterThe following set of procedures requires two persons. One personmust be stationed on the bridge

Página 37 - Temperature protection

Start-up procedures115851-164574 / CActions on the bridgeNote This procedure must be performed simultanously with the nextprocedure; Actions in the so

Página 38 - 2 INSTALLATION PLANNING

Simrad SP60116851-164574 / CBlank pageThis page is intentionally left blank. It allows you to remove the next test procedure fromthe manual, and bring

Página 39 - 2.2 Location of the Hull Unit

Start-up procedures117851-164574 / CActions in the sonar roomNote This procedure must be performed simultanously with the previousprocedure; Actions o

Página 40

Simrad SP60118851-164574 / C9.11 Alignment of the sonar pictureIndependent of the hull unit orientation, the alignment is alwaysdefined as:• the angle

Página 41 - 2.3 Sonar room requirements

Start-up procedures119851-164574 / Ce Observe the Sonar transceiver configuration menuappear at the bottom of the menu field.f Press the Alignment but

Página 42

Simrad SP60120851-164574 / C9.12 Adjusting the stabilisation sensor offsetIndependent of the hull unit orientation, the o ffset of thestabilization se

Página 43 - Figure 3 Sonar room example

Start-up procedures121851-164574 / CProcedure: To enter the stabilisationoffset angleObserve the following procedure to enter the offset stabilization

Página 44

Simrad SP60122851-164574 / C9.13 Setting own ship parametersShip dimensionsTo get the correct size of the vessel symbol on the display, thelength and

Página 45 - 3SONARTRUNK

Start-up procedures123851-164574 / CFigure 41 Origodefinition-Y+Y+X-XOrigo(CD6748)4 Press the X Position button and enter the correct value.5 Press th

Página 46 - 3.2 Protection

Simrad SP60X851-164574 / CNotes

Página 47 - 3.4 Principles

Simrad SP60124851-164574 / C10 TESTING THE PERIPHERAL EQUIPMENT10.1 IntroductionThe physical connections of the peripehral sensors has beenpreviously

Página 48 - Side view

Testing the peripheral equipment125851-164574 / C10.2 GeneralDefault interface settingsThe sensor settings are all preset to these recommendedconnecti

Página 49 - Installation trunk

Simrad SP60126851-164574 / C13 Press Close to finish.If you enter a wrong value and the sensor i nterface does not work,you can change the parameters

Página 50 - 4HULLUNIT

Testing the peripheral equipment127851-164574 / CFigure 43 The Object Inspector7 Select SensorIOControl on the list by pressing on the + signin front

Página 51 - 4.2 Hull unit models

Simrad SP60128851-164574 / C10.3 Speed logIntroductionThe speed log can come from three different sensor types. Tick offfor the type which will be con

Página 52 - 4.3 Unpacking

Testing the peripheral equipment129851-164574 / C1 Access the I/O Setup menu.2 Select Sensors in the I/O Setup menu, then Speed andfinally Speed Log.3

Página 53 - 4.4 Mounting

Simrad SP60130851-164574 / C10.4 Course gyroIntroductionThe heading can come from two different sensor types. Tick off forthe type which will be conne

Página 54 - 4.5 Bleeding air

Testing the peripheral equipment131851-164574 / C3 Observe the Sensor Config submenu appears at the bottomof the menu field.4 Change the settings in t

Página 55 - 4.6 Mechanical support

Simrad SP60132851-164574 / C10.5 (D)GPSObserve the following procedure t o test the GPS input:1 Access the I/O Setup menu.→ A procedure for this is lo

Página 56 - 4.7 Transducer alignment

Testing the peripheral equipment133851-164574 / C10.6 Echo sounderThe SP60 Processor Unit can read the depth information from anecho sounder on standa

Página 57 - 4.8 Installation check-list

Installation manualXI851-164574 / CHigh voltage safety warningPrecautionary measuresThe voltages used to power this equipmentare potentially lethal. E

Página 58 - 5 TRANSCEIVER UNIT

Simrad SP60134851-164574 / C10.7 Trawl systemObserve the following procedure to test the trawl system interface.1 Access the I/O Setup menu.→ A proced

Página 59 - Transceiver Unit - side view

Testing the peripheral equipment135851-164574 / C10.8 Purse seine systemObserve the following procedure to test the purse seine interface.1 Access the

Página 60

Simrad SP60136851-164574 / C10.9 Radio buoy systemObserve the following procedure to test the radio buoy systeminterface.1 Access the I/O Setup menu.→

Página 61

Testing the peripheral equipment137851-164574 / C10.10 Current meter systemObserve the following pr ocedure to test the Current Meter systeminterface.

Página 62 - 6 WHEELHOUSE UNITS

Simrad SP60138851-164574 / C11 FINAL TESTS AND MEASUREMENTS11.1 IntroductionIn order to verif y that the sonar works properly, the followingmeasuremen

Página 63 - 6.2 Location

Final tests and measurements139851-164574 / C11.2 Source level (SL) measurementsPreparationsThe procedure calls for a test hydrophone. Prior to use, f

Página 64 - SonarProcessorUnit

Simrad SP60140851-164574 / CFigure 44 Source Level (SL) measurementsTX enable(CD5873)TXenableExternal triggerVertical inputOscilloscopet (ms)5 to 10 m

Página 65 - Loudspeaker

Final tests and measurements141851-164574 / C9 Access the Horizontal menu.10 Push the Ping Sector button, and observe the P ing Sectorsubmenu appear a

Página 66 - 6.3 Display unit

Simrad SP60142851-164574 / CSL = U Hydr -- M + 20 log rU Hydrophone dB//1V --12.1OMNIM totaldB//1V/µPa--209.620 log r dB 17.5SL OMNIdB//µPa215.0U Hydr

Página 67 - 6.4 Sonar Operating Panel

Final tests and measurements143851-164574 / C11.3 Receiving voltage response (VR)PreparationsIn order to measure the receiving voltage response, use t

Página 68 - Fastening screwsLocking pin

Simrad SP60XII851-164574 / CArtificial respiration1 Kneel besides t he victim’s head. Place onehand under his neck and lift, allowing hishead to fall

Página 69 - 6.6 Sonar Interface Unit

Simrad SP60144851-164574 / C8 Enter the measured hydrophone voltage U(p-p) into theMeasurement and calculation results table, and calculate theU Hydr

Página 70 - 6.7 Loudspeaker

Final tests and measurements145851-164574 / CMeasurement terminationThe voltage response measurements have now been completed.Remember to restore all

Página 71 - 7 CABLE LAYOUT

Simrad SP60146851-164574 / C11.4 Noise/speed curvePreparationsIn order to make a noise/speed curve for the ship, make thefollowing settings in the SP6

Página 72 - 7.2 System cabling

Final tests and measurements147851-164574 / CSpeed(Knots)Bearing(Knots)--120° -- 6 0 ° 0° +60° +120° +180°02468101214Table 8 Noise measurements8 When

Página 73

Simrad SP60148851-164574 / CSpeed(Knots)Bearing 0 degrees(Knots)Stable speed Acceleration Retardation02468101214Table 9 Noise verification4 Make a das

Página 74 - 7.3 Cable specifications

Final tests and measurements149851-164574 / C+10dB+8NOISE/SPEED CURVEFOR 0° BEARING WITHdB+6MAXIMUM GAINdB+4_________STABLE SPEED---------ACCELERATION

Página 75

Simrad SP60150851-164574 / C12 TECHNICAL SPECIFICATIONS12.1 Power specificationsSonarProcessorUnitMC70• Voltage:- Nominal: 115 / 230 Vac, single phase

Página 76 - 7.4 Wheelhouse cabling

Technical specifications151851-164574 / CSonarProcessorUnitMC70• Weight: Approximately 15 kg• Dimensions (WDH): 452 x 410 x 267 mm→ Refer to the outli

Página 77 - Connections

Simrad SP60152851-164574 / C→ Refer to drawing 830-113361 on page 194.12.3 Environmental specificationsSonarProcessorUnitMC70• Operational temperature

Página 78

Technical specifications153851-164574 / C12.4 Telegram formatsIntroductionThe SP60 can send and receive information from several differentperipherals.

Página 79 - - Operating panel (USB)

Introduction1851-164574 / C1INTRODUCTION1.1 Purpose and descriptionIntroductionThe purpose of this manual is to provide the information and basicdrawi

Página 80 - (CD5718)

Simrad SP60154851-164574 / CNMEA 0183The NMEA 0183 Standard is the most common protocol used forreceiving and transmitting sensor data. The following

Página 81

Technical specifications155851-164574 / CGyroThe sonar can receive the following gyro telegrams.• Heading, magnetic• Heading, trueHeading, magnetic$??

Página 82 - Live Neutral

Simrad SP60156851-164574 / CSpeed logThe SP60 can interface to an external speed log via Ethernet, or aserial line using the NMEA 0183 standard for re

Página 83 - (CD3117)

Technical specifications157851-164574 / CTimeThe SP60 software provides an interface to an external timesynchronisation unit. The communication can ta

Página 84 - (CD5821)

Simrad SP60158851-164574 / CTrawl systemsThe SP60 interfaces a trawl system via Ethernet or on a serial line.The serial interface uses either the NMEA

Página 85

Technical specifications159851-164574 / CTrawl position in cartesian co-ordinates@IITPC,x,M,y,M,z,M<cr><lf>where (from left towards right)

Página 86

Simrad SP60160851-164574 / CTrawl headrope to footrope and bottom@IIHFB,x.x,M,y.y,M<cr><lf>where (from left towards right):Component Conte

Página 87 - C16 - Transducer cable

Technical specifications161851-164574 / CTrawl to shoal distance@IITTS,x,M,y,P,z,M<cr><lf>where (from left towards right):Component Conten

Página 88 - Cable trays

Simrad SP60162851-164574 / CITI OutputsThe SP60 t ransmits the following NMEA telegrams to the ITIsystem.• Tracked target position or markerTracked ta

Página 89 - Grounding

Technical specifications163851-164574 / CFS3300 Trawl systemThe serial output of the FS3300 system sends a 2-byte binary depthvalue. With a measuremen

Página 90 - Cable identification

Simrad SP602851-164574 / C1.2 System diagramA simplified SP60 system diagram is shown.Legend:(A) = Colour display(B) = Keyboard(C) = Sonar Processing

Página 91 - 8 PERIPHERAL EQUIPMENT

Simrad SP60164851-164574 / CGlobal Positioning System (GPS)The SP60 can interface an external Global Positioning System(GPS) via Ethernet or by a seri

Página 92 - (CD7014)

Technical specifications165851-164574 / CGlobal positioning system fix data$??GGAhhmmss.ss,ddmmhh,,N,dddmm.hh,W,hhmmss.ss,a,x,xx,x.x,x.x,M,x.x,M,x.x,x

Página 93 - 8.2 Speed log connection

Simrad SP60166851-164574 / CEcho sounderThe SP60 interfaces an external echo sounder via Ethernet or aserial line for reception of depth information.

Página 94

Technical specifications167851-164574 / CSounder depth below surface (Special)This telegram has been developed by Simrad.$SDDBS,,,y.y,M,,,tttttt<cr

Página 95 - 8.3 Course gyro connection

Simrad SP60168851-164574 / CSea current sensorThe SP60 interfaces to an external sensor for reception of seacurrent data. The interface is made via Et

Página 96 - 8.4 (D)GPS connection

Technical specifications169851-164574 / CWind sensorThe SP60 interfaces an external wind sensor via Ethernet or a serialline using the NMEA 0183 stand

Página 97 - 8.5 Echo sounder connection

Simrad SP60170851-164574 / CWind speed and angle (relative)$??VWR,x.x,a,x.x,a,A<cr><lf>where (from left towards right):Component Content??

Página 98 - 8.6 Trawl system connection

Drawing file171851-164574 / C13 DRAWING FILE13.1 OverviewThis chapter contains cable details and installation drawings.Cable details→ C1 - W301 AC pow

Página 99

Simrad SP60172851-164574 / CHull unit, outline dimensions→ SP60 Hull Unit Outline, refer to page 193.Mounting trunk, outline dimensions→ SP60 Sonar Mo

Página 100 - 8.8 Current meter

Drawing file173851-164574 / CInternal control and communicationcablesThese drawings detail the three cables used between the SP60Sonar Processor Unit

Página 101 - 8.9 Radio buoys

Introduction3851-164574 / CHGEACDBFWheelhouseSonar room(CD6479B)115/230 Vac115/230 Vac115/230 Vac230/380/440 Vac3-phaseFigure 1 SP60 system diagram

Página 102 - Simrad SP60

Simrad SP60174851-164574 / CC6 - Cheapernet communicationThis is the Cheapernet signal cable between the Sonar InterfaceUnit and the Sonar Processor U

Página 103 - 9 START-UP PROCEDURES

Drawing file175851-164574 / CSonar Interface UnitLoudspeakerThe loudspeaker cable is physically connected to the loudspeakerunit, and as such a part o

Página 104 - J3 connector for C1

Simrad SP60176851-164574 / CSerial linesThe Sonar Interface Unit provides seven serial linecommunication ports. These are available on terminal blocks

Página 105 - → Refer to figure 30

Drawing file177851-164574 / CPulse speed logThis interface has been provided for a pulse speed log.W208C / Rev.APulse log621811471039125Sonar Interfac

Página 106 - Supply voltage (Vac):

Simrad SP60178851-164574 / CC15 - Transceiver Unit interfaceThis is the main interconnection cable between the Sonar InterfaceUnit and the Transceiver

Página 107 - 9.4 Starting up the Hull Unit

Drawing file179851-164574 / CSynchronizationThis cable allows external synchronization of the sonar’stransmission.W208F / Rev.ASynchronization62181147

Página 108

Simrad SP60180851-164574 / CTransceiver Unit to Motor Control UnitThis is the main intercommection cable between the SP60Transceiver Unit and the Moto

Página 109 - Apply 3-phase AC power

Drawing file181851-164574 / CStandard AC power cableThis cable is a standard three-wire power cable. It is commerciallyavailable in standard lengths,

Página 110 - 380 / 440 Vac

Simrad SP60182851-164574 / CPower to Hull UnitThis cable is used to connect AC power to the Motor Control Unit,and thus also to the hull unit’s hoist

Página 111 - Functional check with power

Drawing file183851-164574 / CEthernet with RJ45This cable contains the Ethernet connection. RJ45 plugs are usedto terminate the cable. Note that these

Página 113 - (CD7010)

Simrad SP604851-164574 / C1.3 Scope of supplyMain unitsThe standard Simrad SP60 sonar system is comprised of thefollowing main units:Unit Order number

Página 114 - Display set-up

Simrad SP60184851-164574 / CStandard VGA cableThis is a standard display cable used to connect the video signals.The cable is normally physically fast

Página 115 - Functional test

Drawing file185851-164574 / CStandard USB cableThis is a standard commercial USB cable terminated with A andB plugs in either ends. The cable can be u

Página 116 - Horizontal gain and range

Simrad SP60186851-164574 / COperator panelThis cable is used to connect the Operator Panel to the SonarProcessor Unit and Sonar Interface Unit. The ca

Página 117 - View menu

Drawing file187851-164574 / C13.3 Installation drawingsThe SP60 installation drawings are provided on the next pages.

Página 118

Simrad SP60188851-164574 / C834-204688Rev.APage 1 of 1(CD5862)Sonar Operating PanelOutline dimensions150370321016All measurements in mm.The drawing is

Página 119 - Power off

Drawing file189851-164574 / C410375202441452267N/ARev.APage 1 of 1(CD7006A)MC70 Sonar Processing UnitOutline dimensionsNote:All measurements are in mm

Página 120 - Preparations

Simrad SP60190851-164574 / C149313Ø7 mm253280(CD7026B)N/ARev.APage 1 of 1(CD7026B)Sonar Interface UnitOutline dimensionsNote:All measurements are in m

Página 121 - Checking the bridge functions

Drawing file191851-164574 / C520470750545Door not hinged857542071AiroutletAir inletTransducercable plug(fastened witheight bolts)Extender through insu

Página 122

Simrad SP60192851-164574 / C110 47110TBDRev.APage 1 of 1(CD6366B)Standard loudspeakerOutline dimensionsAll measurements in mm.

Página 123

Drawing file193851-164574 / C3751645ø5801000ø508755(990)Standard SP-trunkTBDRev.APage 1 of 1(CD6243)SP60 Hull UnitOutline dimensionsAll measurements i

Página 124 - Blank page

Introduction5851-164574 / CThe following option is available:Hull Unit Specifications Order numberSP61 1.2 m / 24 knots SP6--207349Installation trunkT

Página 125

Simrad SP60194851-164574 / CM160.516 HOLES,SPACING 22.5OClassification society marking±2ø540ø460+1-0ø580+-210(508)990+-3(12.5)45°1018-0+122.5°830-113

Página 126

Drawing file195851-164574 / C830-113362Rev.APage 1 of 1(CD5846)Blind coverfor sonar trunkø540ø580+-218+-0.50.516 holes, spacing 22.5o13+-20

Página 127

Simrad SP60196851-164574 / C14 INSTALLATION REMARKSUse these pages to document comments and remarks concerningthe installation. When the installation

Página 128 - 9.9 Self-noise test

Installation r emarks197851-164574 / C---------------------------------------------------------(Party / Date / Signature)-----------------------------

Página 131 - Actions on the bridge

E 2003 Simrad ASISBN 82-8066-006-2Simrad ASStrandpromenaden 50Boks 1113191 HortenTelephone: 33 03 40 00Facsimile: 33 04 29 87Internet: www.simrad.comA

Página 133 - Actions in the sonar room

Simrad SP60Installation manualSimrad SP60Installation manualSimrad SP60Installation manualSimrad SP60Installation manual

Página 134

Simrad SP606851-164574 / C1.4 Peripheral equipmentRequired inputsThe Simrad SP60 sonar system requires input from both a speedlog and a course gyro. I

Página 135

Introduction7851-164574 / CNote that in addition to navigational data, the (D)GPS may also beused for the input of speed log inf ormation. Most (D)GPS

Página 136

Simrad SP608851-164574 / C1.5 Supply conditionsPurposeThe following supply conditions are applicable to standard SimradSP60 deliveries and associated

Página 137 - button

Introduction9851-164574 / C1.6 General safety rulesThe system operates on 115 and/or 230 / 380 / 440 Vac, 50/60 Hz.WARNING This voltage can be lethal.

Página 138 - , and finally Transducer

Simrad SP6010851-164574 / C1.7 Installation requirementsResponsibility and approvalThe Simrad SP60’s Hull Unit sleeve has been approved by DetNorske V

Página 139 - , and finally GPS

Introduction11851-164574 / CDry dockingMake sure that ample clearance under the sonar trunk and/orprotection blister is provided when dry docking the

Página 140 - 10.1 Introduction

Simrad SP6012851-164574 / C1.8 Equipment handlingIntroductionThis chapter describes how to transport, pack and unpack, clean,preserve and store electr

Página 141 - 10.2 General

Introduction13851-164574 / CHeavy units may be equipped with lifting lugs for transportationby crane within the workshop or installation area. Before

Página 142 - Serial line inspection

Simrad SP60Low frequency fishery sonarWARNINGThe sonar must never be powered up when the ship isin dry dock. The transducer will be damaged if ittrans

Página 143

Simrad SP6014851-164574 / C- “Special circumstances” may be suspected damage to thecrate and its content, or inspections by civil authorities.- If any

Página 144 - 10.3 Speed log

Introduction15851-164574 / CInspection and unpackingInspectionAn inspection must be carried out immediately after the unit(s)have arrived at their des

Página 145 - Speed data from (D)GPS

Simrad SP6016851-164574 / C• If the carton has been closed using staples, remove the staplesfrom the carton as you open it. This will reduce the possi

Página 146 - 10.4 Course gyro

Introduction17851-164574 / CThe transducer face must be protected by a rigid, padded cover(e.g. a wooden box lined with foam rubber) all the time it i

Página 147 - Related topics

Simrad SP6018851-164574 / CCleaning cabinetsIf the unit may have been exposed to salt atmosphere while it wasin use, it must be thoroughly cleaned bot

Página 148 - 10.5 (D)GPS

Introduction19851-164574 / C• All surfaces must be inspected for signs of corrosion, eg.flaking/bubbling paint, stains etc. Damaged or suspect areasmu

Página 149 - 10.6 Echo sounder

Simrad SP6020851-164574 / C• Large units must be placed in a suitable cardboard box orwooden crate. The unit must be protected against physicaldamage

Página 150 - 10.7 Trawl system

Introduction21851-164574 / CCaution If, for any reason, it is necessary to move the circuit board orcomponents from the conductive service mat, they m

Página 151 - 10.8 Purse seine system

Simrad SP6022851-164574 / C2 INSTALLATION PLANNINGNote For installation in a previously installed trunk system, first readthe information about sonar

Página 152 - 10.9 Radio buoy system

Installation planning23851-164574 / C2.2 Location of the Hull UnitFore and aftThe Hull Unit should preferably be located within 1/10 to 1/3 thevessel’

Página 153 - 10.10 Current meter system

NoteSimrad AS makes every effort to ensure that the information contained within thisdocument is correct. However, our equipment is continuously being

Página 154 - 11.1 Introduction

Simrad SP6024851-164574 / C• Overboard discharges• Dents in the hullAll appendages to the hull, indentations and pipe in/outlets arepotential sources

Página 155 - Test procedure

Installation planning25851-164574 / C2.3 Sonar room requirementsSizeThe sonar room must be dimensioned to house both the Hull andthe Transceiver Unit.

Página 156 - (CD5873)

Simrad SP6026851-164574 / CIn the sonar room, the air inlet should be located in close to the deckand the outlet as high as possible. A funnel shaped

Página 157 - → Refer to table 4

Installation planning27851-164574 / CFigure 3 Sonar room exampleLightingMinimum loadcapacity: 2 tonnesBulkheadstepsTransceiver UnitMotor Control Unit(

Página 158 - Measurement termination

Simrad SP6028851-164574 / CTransceiver UnitTransducer cable(Total length 3.5 m)400 (*)Min.600Hatch(Minimum size550 x 1000 mm)1000 (*)500 (*)(*) = Reco

Página 159 - Procedure

Installation trunk29851-164574 / C3SONARTRUNK3.1 Mounting of the trunkThe location of the sonar trunk must be carefully selected.→ Refer to the Instal

Página 160

Simrad SP6030851-164574 / C3.2 ProtectionProtecting blisterA steel blister must be fitted for protection. The blister shown iswelded to the shell plat

Página 161

Installation trunk31851-164574 / C3.4 PrinciplesThe drawings on the next pages illustrate the installation of thesonar trunk.

Página 162 - 11.4 Noise/speed curve

Simrad SP6032851-164574 / CFigure 6 Trunk installation with extension and oil-filled blister.2.5-3xEBDAFore-and-aft viewThickness of platesKnee-plates

Página 163 - Problems with flow noise

Installation trunk33851-164574 / CFigure 7 Trunk installation with open protection blister.(CD1884)2.5 - 3xEBDAFore-and-aft viewThickness of platesKne

Página 164

Installation manualI851-164574 / CSectionsThis document is the Installation manual for the Simrad SP60 sonar system. It provides theinformation and te

Página 165 - Figure 45 Noise speed plot

Simrad SP6034851-164574 / C4HULLUNIT4.1 IntroductionThe hull unit is a crucial part of the sonar system. Due to itsphysical size and weight, and the f

Página 166 - 12 TECHNICAL SPECIFICATIONS

Hull unit35851-164574 / C4.2 Hull unit modelsThe SP60 sonar may be delivered with one of two different hullunit models.• SP60 - This is the “standard

Página 167

Simrad SP6036851-164574 / C4.3 UnpackingWARNING Do not remove the transducer protection fromthe transducer until just before the Hull Unit isto be low

Página 168

Hull unit37851-164574 / C4.4 MountingThe Hull Unit should normally be oriented with thehoisting/lowering motor pointing aft.Figure 9 Recommendedorient

Página 169 - 12.4 Telegram formats

Simrad SP6038851-164574 / C4.5 Bleeding airTo avoid damage to the transducer by the transmission in air insidethe trunk, a pipe with a minimum inside

Página 170 - NMEA 0183

Hull unit39851-164574 / C4.6 Mechanical supportTo ensure the safety of the sonar system and the vessel, it is veryimportant that the mechanical suppor

Página 171 - Heading, true

Simrad SP6040851-164574 / C4.7 Transducer alignmentNote that the transducer should not be mechanically aligned eventhough the Hull Unit is oriented di

Página 172 - Speed log

Hull unit41851-164574 / C4.8 Installation check-listRefer to section Sonar room requirements when you fill in thefollowing check list.INSTALLATION CHE

Página 173 - Time and date

Simrad SP6042851-164574 / C5 TRANSCEIVER UNITIntroductionNote The Transceiver Unit must be mounted as a complete unit, i.e. thedoor should not be open

Página 174 - Trawl systems

Transceiver unit43851-164574 / CFigure 11 Mounting the brackets for theTransceiver Unit - side viewAngle bars with threadedholes for shock absorbers.B

Página 175 - Depth of trawl below surface

Simrad SP60II851-164574 / CRemarksReferencesFurther information about the SP60 system may be found in the following manuals:• SP60 Operator manualThe

Página 176

Simrad SP6044851-164574 / CFigure 12 Mounting the brackets for theTransceiver Unit - forward view(CD1988A)App. 40150Min.150Min.Recommended 1100-1200Mi

Página 177 - Trawl to shoal distance

Transceiver unit45851-164574 / CFigure 13 Mounting the Transceiver Unit(CD3110A)

Página 178

Simrad SP6046851-164574 / C6 WHEELHOUSE UNITS6.1 OverviewThis chapter explains how to install the SP60 hardware unitsnormally positioned in the wheelh

Página 179 - FS3300 Trawl system

Wheelhouse units47851-164574 / C6.2 LocationIntroductionOn board routines should be thoroughly discussed with the captainwhen selecting the locations

Página 180 - Geographical position

Simrad SP6048851-164574 / CDisplay unitThe display unit should be located so that it is best protected fromglare which reduces readability. I t may be

Página 181

Wheelhouse units49851-164574 / CLoudspeakerChoosing a location and installation of the loudspeaker should bedone with r egar d to utility.The compass

Página 182 - Echo sounder

Simrad SP6050851-164574 / C6.3 Display unitDifferent display units are available as optional equipment. Forinstallation and operation of the chosen di

Página 183

Wheelhouse units51851-164574 / C6.4 Sonar Operating PanelObserve the following procedure. To ensure correct operation, tickoff every item when the act

Página 184 - Water propagation speed

Simrad SP6052851-164574 / C6.5 Sonar Processor Unit (MC70)The MC70 Sonar Processor Unit should be mounted on the deckor shelf inside a console, cabine

Página 185 - Wind speed and angle

Wheelhouse units53851-164574 / C6.6 Sonar Interface UnitThe Sonar Interface Unit should be mounted vertically with thecable inlet downwords on a side

Página 186

Installation manualIII851-164574 / CTable of contents1 INTRODUCTION 1...1.1 Purpose and description 1...

Página 187 - 13 DRAWING FILE

Simrad SP6054851-164574 / C6.7 LoudspeakerThe loudspeaker should be mounted on the deckhead or anywherepractical close to the display unit.Provide eno

Página 188 - 13.2 Cable details

Cable layout and connections55851-164574 / C7 CABLE LAYOUT7.1 IntroductionThis chapter describes the installation requirements f or SP60system wiring.

Página 189 - Drawing file

Simrad SP6056851-164574 / C7.2 System cablingCable layoutCables are identified according to individual cable numbers anddrawing numbers listed on the

Página 190 - C6 - Cheapernet communication

Cable layout and connections57851-164574 / C115 / 230 Vac mains C1115 / 230 Vac mains C3*C18* AC MainsSonar Processor UnitOperating PanelDisplay UnitC

Página 191 - Sonar Interface Unit

Simrad SP6058851-164574 / C7.3 Cable specificationsThe list below specifies each cable used on the SP60 sonar.References are made to detailed cable dr

Página 192 - W208B / Rev.A

Cable layout and connections59851-164574 / CC11-C14 / C20-C25 Peripheral equipmentThese are cables used to interface peripheral equipment. They aredes

Página 193

Simrad SP6060851-164574 / C7.4 Wheelhouse cablingIntroductionConnections to the Sonar Processor Unit are made on theconnectors on the rear side of the

Página 194 - Transceiver Unit

Cable layout and connections61851-164574 / CConnectionsThe illustrations below identify the main connectors on the SonarProcessor Unit and the Sonar I

Página 195

Simrad SP6062851-164574 / CCablesC1 - AC Power to the Display UnitThis is a standard mains supply cable. It is included in the deliverywith the option

Página 196 - Motor Control Unit E301

Cable layout and connections63851-164574 / C2 Secure the plug on the rear side of the Sonar Processor Unitwith the bracket.If the delivered cable conn

Página 197 - Standard AC power cable

Simrad SP60IV851-164574 / C2 INSTALLATION PLANNING 22...2.1 General 22...2.2 L

Página 198 - Power to Hull Unit

Simrad SP6064851-164574 / C→ Figure 21 shows the connection to the Operating Panel.→ The figure on page 61 shows the connection to the SonarProcessing

Página 199 - Ethernet with RJ45

Cable layout and connections65851-164574 / CC10 - LoudspeakerThis is a special cable for connections between the Loudspeakerand the Sonar Interface Un

Página 200 - Standard VGA cable

Simrad SP6066851-164574 / C7.5 Sonar room cablingIntroductionAll sonar room cabling must be performed as specified. The cablenumbers used to identify

Página 201 - Standard USB cable

Cable layout and connections67851-164574 / C2 Terminate the cable shielding.→ Cable shielding is shown in figure 23.Cablemainscreen(CD3117)Figure 23 T

Página 202 - Operator panel

Simrad SP6068851-164574 / CFigure 24 Connections tothe Motor Control UnitC19C17REMOTES 302HOIST STOPLOWERHAND CRANKS 303(CD5821)CablestripE301

Página 203 - 13.3 Installation drawings

Cable layout and connections69851-164574 / CUse the following procedure for connecting the cable C15 to theTransceiver Unit. To ensure correct operati

Página 204

Simrad SP6070851-164574 / CC18-ACpowertotheTransceiverUnitThis cable is included in the delivery. It is used for the mains supplyto the Transceiver Un

Página 205

Cable layout and connections71851-164574 / C2 Set the mains voltage selector switch S201 on the PowerSupply and S203 on the HV Power Unit to correspon

Página 206

Simrad SP6072851-164574 / C7.6 Basic cabling requirementsCable traysAll permanently installed cables associated with the system mustbe supported and p

Página 207

Cable layout and connections73851-164574 / CRadio Frequency interferenceAll cables that are to be permanently installed within 9 m (30 ft)of any sourc

Página 208

Installation manualV851-164574 / C6 WHEELHOUSE UNITS 46...6.1 Overview 46...

Página 209

Simrad SP6074851-164574 / CMetallic casings, pipes and conduits must be grounded, and whenfitted with joints these m ust be mechanically and electrica

Página 210

Connecting peripher al equipment75851-164574 / C8 PERIPHERAL EQUIPMENT8.1 GeneralIntroductionIt is not necessary to make the connection of the periphe

Página 211

Simrad SP6076851-164574 / CPhysical connections to the Sonar Interface UnitThe figure below shows the positions for the different auxiliaryconnections

Página 212 - 14 INSTALLATION REMARKS

Connecting peripher al equipment77851-164574 / C8.2 Speed log connectionOverviewThe sonar can read the speed information from one of thefollowing thre

Página 213

Simrad SP6078851-164574 / CSpeed log with RS-232 outputThe sonar can also read the speed log data from a RS-232 serial linewith a standard NMEA 0183 t

Página 214

Connecting peripher al equipment79851-164574 / C8.3 Course gyro connectionOverviewThe SP60 sonar can read the course information from an RS-232serial

Página 215

Simrad SP6080851-164574 / C8.4 (D)GPS connectionA (D)GPS may be connected to the SP60 sonar to indicate thelatitude and longitude position of the vess

Página 216 - ISBN 82-8066-006-2

Connecting peripher al equipment81851-164574 / C8.5 Echo sounder connectionTo provide depth information on the sonar, an echo sounder withstandard NME

Página 217

Simrad SP6082851-164574 / C8.6 Trawl system connectionThe SP60 sonar can read the trawl data from a Simrad FS Trawlsonar or ITI (Integrated Trawl Inst

Página 218

Connecting peripher al equipment83851-164574 / C8.7 Purse seine system connectionTo provide purse seine depth information on the sonar’s display,Simra