SimradMS70
Performance,MultibeamOperatorStation
Hardware
Processor:PentiumIVorlater
Processorspeed:Minimum3GHz
Memorycapacity:Minimum2Gb
Hard-diskcapacity:Minimum20Gb
Type:SimradAPC12ProcessorUnit
Software
Operatingsystem:Microsoft®WindowsXP®
Scienticmultibeamsonarapplication:CustomSimradsoftware
Performance,TransceiverUnit
TRCBeamformingcomputers:DellPowerEdgeR610
TRXUTransceivers:CustomMS70
Ethernetswitch:HPProcurve2910
Performance,PowerSupplyUnit
Outputvoltages:
+6Vdc,20A
+12Vdc,10A
+75Vdc,4A
NominalpowerdeliveredtoTRXUload:270W
Ethernetcable:
Length:10m
Type:CA T5
DCvoltagecables:
Maximumlength:10m
Totalweight,allpowercables:14kg
Performance,Transducerarray
Technology:Ceramicpolymercomposite
Numberofindividualelements:800
Frequencyrange:70to120kHz
Maximumtransducerdepth:15m