Cablelayoutandinterconnections
TRXUracksDCinputwiring
ThesearetheDCcablesfromtheDCterminalboardsattherearofthethreeTRXU
racks.ThreeAmphenolplugsconnectthesecablestothePowerConnectorPanel
atrearsideoftherack.
-75V +75V
-12V -12V
-6V -6V +6V +6V
Neutral GroundLive
F
F
E
G
D
H
C
I
B
J
A
E
E
F
D
D
G
C
C
H
B
B
I
A
A
J
+12V +12V
Amphenol6-pinfemaleconnector
Femalemainsconnector
Amphenol10-pinmaleconnector
Amphenol10-pinfemaleconnector
W246C
RevA
Powercabinets,DCsupplyto TRXU
Cablespecications
Conductors:1.5mm²
Screen:Separateconductor
Voltage:600V
Maximumdiameter:LimitedbythemountingpinsontheAmphenolconnectors.