Simrad FS25 Guia do Utilizador Página 45

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 44
901-10037001/1.1 FS 20/25 Operators Manual
Page 4.8 FS 20/25 Installation, System Set-Up and Test
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
D- In the “FS25” position, 200 VDC will be provided to the trawl cable. You
select the FS25 position when you have a FS900/FS925 Housing under
water unit connected to the trawl cable, utilizing a FS925 forward-looking
sonar head and an FS3300, TS10, TS15, or TS15S sonar head and a sensor
module.
Note!
To test the FS25 trawl sonar heads connected to the test cable,
you will have to position the voltage selection to FS20.
Warning!
. If you connect an FS3300 330kHz or 120kHz sonar head to the
trawl cable with the switch set to FS25, 200 VDC, you will damage
your trawl sonar head. The FS25, 200VDC, will be used with an
FS 925 90kHz Stand Alone Sonar Head, or a full FS900/925
Deployment Package with any combination of Vertical Heads
(FS3300, TS10,TS15 or TS15S) connected to the trawl cable.
4.2.10 Connection to Cable Winch/Slip-Rings
The connection between the FS 20/25 TTM Interface unit and the cable winch/slip-
rings should be made with an 18 GA., or heavier, shielded twisted pair cable. The
connection to the control unit is made using the 3-pin MS connector supplied in the
TTM module accessory kit. To minimize noise interference on the cable, the shield
of the cable should be attached to the connector.
Note!
The shield of the cable between the FS 20/25 TTM module and
the slip-rings should be connected at the TTM module, but NOT
at the slip-rings.
4.2.11 Interfacing to a Simrad Echo Sounder
The FS 20/25 HP PC processor may be connected to a Simrad echo sounder for
display of the trawl unit depth on the sounder. This is made via the RS232 serial
port “B” on the rear panel of the control unit (DB-9 connector labeled "RS-232" “B”
port). The processor will output the Temperature and the Depth from the trawl
sensor module in an NMEA 0183 format.
If the port “B” is not available, you will have to install an additional serial card. The
recommended type of serial card to install and the installation procedure are provided
in Part 7 “Attachments”. Interconnect cable not supplied.
Vista de página 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 107 108

Comentários a estes Manuais

Sem comentários