INSTRUCTION MANUAL
20221487 / B 23
4.4 Operation
Turning the repeater ON
DIMMER POWER
The repeater holders and the repeater stand have a power button
on the connection box.
When the cables are connected and the jumper set in the control
unit according to the previous pages, the repeater is turned on by
switching the power button.
If the signal is invalid or missing after 1 second, the repeater will
indicate this by rotating the dial back and forth +/-35° around the
last known heading.
When the defined input signal is lost, the power must be
switched off and on again. If the cable not is connected via an
external switch, the cable must be disconnecting and
reconnected again to define a new input signal.
Adjusting display illumination
The rotary button is used for adjusting the illumination on
AR81/83 repeater. Rotating the button in clockwise direction
will increase the light intensity, while the light intensity will be
decreased when the button is turned counter-clockwise.
4.5 Commissioning
Perform the following tests when commissioning the repeater:
1 Ensure that the mechanical installation and cable
connection has been completed according to the
description on previous pages
2 Turn the repeater on.
- The repeater will align itself to zero and then to the
transmitted gyro heading
3 Ensure that the lighting is set to a suitable level. Adjust if
necessary with the dimmer button