INSTRUCTION MANUALSimrad HS50 Heading Sensor
Simrad HS50 Heading Sensor 2 20221081 / F High-precision heading is derived from the fixed-distance dual GPS antenna arrangement in the Sensor unit,
INTRODUCTION 20221081 / F 3 1.2 About this manual This manual is intended as a reference guide for operating, installing and maintaining the HS50 He
Simrad HS50 Heading Sensor 4 20221081 / F Abbreviations and acronyms CEP Circular Error Probability COG Course Over Ground DGPS Differential GPS DU H
TECHNICAL SPECIFICATIONS 20221081 / F 5 2. TECHNICAL SPECIFICATIONS 2.1 Health, environment and safety Operation or troubleshooting of HS50 equipme
Simrad HS50 Heading Sensor 6 20221081 / F 2.4 Performance data Heading accuracy, static:...0.3° RMS Head
TECHNICAL SPECIFICATIONS 20221081 / F 7 Processing unit Width: ...287 mm (11.3 in.) Heigh
Simrad HS50 Heading Sensor 8 20221081 / F Processing unit Enclosure material: ...Anodized aluminum Enclosure prot
INSTALLATION 20221081 / F 9 3. INSTALLATION 3.1 General The following parts are supplied with a standard HS50 system: − Sensor unit with 1 meter c
Simrad HS50 Heading Sensor 10 20221081 / F 3.4 Sensor unit Location of the unit The Sensor unit is the most important part of the HS50 system, and g
INSTALLATION 20221081 / F 11 Mechanical installation The Sensor unit may be mounted in the mast or directly on the deck. The dimensional drawing for
Note! Simrad AS makes every effort to ensure that the information contained within this document is correct. However, our equipment is continuously be
Simrad HS50 Heading Sensor 12 20221081 / F Bracket mounting (option) An optional mounting bracket (part no. 20213039) can be delivered from Simrad by
INSTALLATION 20221081 / F 13 Pedestal mounting (option) An optional mounting pedestal (part no. 20213021) can be delivered from Simrad by request. Th
Simrad HS50 Heading Sensor 14 20221081 / F If the Sensor unit connector needs to be reconnected to the cable, the wiring for the cable within the Sen
INSTALLATION 20221081 / F 15 Panel mounting Two mounting methods may be used when panel mounting the HS50 Display unit. A drilling template, part no.
Simrad HS50 Heading Sensor 16 20221081 / F Bracket mounting (option) An optional bracket, part no. 22084941, may be ordered from Simrad. Note! When
INSTALLATION 20221081 / F 17 Display unit cable The 15 m cable to the Processing unit has connector only at the Display unit end. Optional extensions
Simrad HS50 Heading Sensor 18 20221081 / F 3.6 Processing unit The Processing unit is not waterproof and should be mounted vertically in a dry place
INSTALLATION 20221081 / F 19 Cable connections Proceed as follows to connect the cables to the Processing unit: 1 Remove the bottom cover (terminal
Simrad HS50 Heading Sensor 20 20221081 / F The pinout for each terminal is as follows: ALARM GREENPOWC YELLOWP200 DISPLAYGND GREYUNITPWR PINKBUS+ WH
INSTALLATION 20221081 / F 21 Connecting to Simrad equipment The figures on the following pages show how HS50 is connected to Simrad equipment. All eq
INSTRUCTION MANUAL 20221081 / F i Instruction Manual HS50 Heading Sensor This manual is intended as a reference guide for installing, operating and m
Simrad HS50 Heading Sensor 22 20221081 / F J50/J300X Junction unit PROCESSING UNITHS50JUNCTIONJ50 / J300XUNITRX2+RX2-422- OUT422+ OUT232 OUTGNDorP204
INSTALLATION 20221081 / F 23 RGC12 Gyro Compass PROCESSING UNITHS50P203P204orP202,232 OUT422+ OUT422- OUTGNDRGC12TERMINAL BOARDGRXHGRXLTB7 Simrad RA4
Simrad HS50 Heading Sensor 24 20221081 / F 3.7 Software setup procedure This chapter describes a number of installation settings that must be perfor
INSTALLATION 20221081 / F 25 Example: The following example shows how to change the ROT Max value in the Display adjustment submenu using the keys an
Simrad HS50 Heading Sensor 26 20221081 / F Differential corrections The signal cable with the differential corrections is connected to the terminal b
INSTALLATION 20221081 / F 27 Data output The Processing unit has two individually configurable output serial lines. On output line Data output 1 two
Simrad HS50 Heading Sensor 28 20221081 / F Ethernet The Processing unit can output data on Ethernet from terminal J60. In the Ethernet submenu the IP
INSTALLATION 20221081 / F 29 Height aiding For operations with weak satellite geometry the position output can be made more accurate by using height
Simrad HS50 Heading Sensor 30 20221081 / F Expert setup By pressing the SETUP button twice and then holding this button for 5 seconds, an Expert Setu
INSTALLATION 20221081 / F 31 Run mode: Used for switching the HS50 between NORMAL and DEMO mode. DEMO mode is used for simulating input data to the
Simrad HS50 Heading Sensor ii 20221081 / F Document revisions Rev Date Written by Checked by Approved by A 12.06.02 FOS/ B 26.09.02 C 06
Simrad HS50 Heading Sensor 32 20221081 / F The average value for observations from each of the two different systems should then be used, and the off
OPERATING INSTRUCTIONS 20221081 / F 33 4. OPERATING INSTRUCTIONS 4.1 Overview The Display unit is used for setup and operation of the HS50. Each of
Simrad HS50 Heading Sensor 34 20221081 / F FUNCTION REF. PAGE The rotary knob is used for entering values in SETUP submenus, and for adjusting the
OPERATING INSTRUCTIONS 20221081 / F 35 • POS-Q. The quality of the position measurements. Two black bar graphs indicate normal accuracy, one black a
Simrad HS50 Heading Sensor 36 20221081 / F GPS heading, the heading output is determined from the inertial element. The data quality status informati
OPERATING INSTRUCTIONS 20221081 / F 37 Third NAV2/POS display: the Satellite skyplot. This display shows satellites in sight by the Sensor unit, and
Simrad HS50 Heading Sensor 38 20221081 / F In this display, a number of additional information on the heading solution is presented. This informati
OPERATING INSTRUCTIONS 20221081 / F 39 Number of satellites used in the GPS position solution and the number of satellites tracked by GPS antenna no
Simrad HS50 Heading Sensor 40 20221081 / F Invalid Position alarm Activated if the system has been unable to determine position the last two seconds,
OPERATING INSTRUCTIONS 20221081 / F 41 4.5 Operation The HS50 will normally output signals on the serial lines without any involvement from the user
INSTRUCTION MANUAL 20221081 / F iii Contents 1. INTRODUCTION ...1 1.1 HS50 System comp
Simrad HS50 Heading Sensor 42 20221081 / F THIS PAGE INTENTIALLY LEFT BLANK
MAINTENANCE 20221081 / F 43 5. MAINTENANCE 5.1 General Service on the HS50 hardware in the field can consist of: • Replacing damaged cables • Rep
Simrad HS50 Heading Sensor 44 20221081 / F Re-calibration of the Sensor unit The direction of the Sensor unit relative to the vessel's heading h
MAINTENANCE 20221081 / F 45 5.3 Repairs and modifications Repair of the HS50 units is limited to replacement of damaged cables, Sensor unit, Process
Simrad HS50 Heading Sensor 46 20221081 / F No response In normal operation it takes about one minute from the Display unit is powered on until inform
MAINTENANCE 20221081 / F 47 No Differential corrections The possible reason for a white box for differential correction indication (DIF) could be one
Simrad HS50 Heading Sensor 48 20221081 / F Reduced heading indication The reason for reduced heading performance could be one of the following: • Th
FIGURES AND DRAWINGS 20221081 / F 49 6. FIGURES AND DRAWINGS This section contains outline drawings showing the mechanical dimensions of the differe
Simrad HS50 Heading Sensor 50 20221081 / F 6.1 Sensor unit, dimensions Approved :Checked :Subtitle:Title :Issued :Drawing no:Xref file : Project
FIGURES AND DRAWINGS 20221081 / F 51 6.2 Sensor unit bracket, dimensions Approved :Checked :Subtitle:Title :Issued :Drawing no:Xref file : Proje
Simrad HS50 Heading Sensor iv 20221081 / F Cable wiring... 13 Waterproofing the conne
Simrad HS50 Heading Sensor 52 20221081 / F 6.3 Sensor unit pedestal, dimensions Approved :Checked :Subtitle:Title :Issued :Drawing no:Xref file
FIGURES AND DRAWINGS 20221081 / F 53 6.4 Processing unit, dimensions
Simrad HS50 Heading Sensor 54 20221081 / F 6.5 Display unit, dimensions Note! Mounting bracket is optional
PARTS LIST 20221081 / F 55 7. PARTS LIST 7.1 Standard delivery The standard HS50 consists of: Part no. No. Description 20212858 1 HS50 Sensor
INSTRUCTION MANUAL 20221081 / F v Processing unit ... 44 Display unit ...
Simrad HS50 Heading Sensor vi 20221081 / F THIS PAGE INTENTIALLY LEFT BLANK
INTRODUCTION 20221081 / F 1 1. INTRODUCTION 1.1 HS50 System components Simrad HS50 is a GPS compass that provides true heading output with position
Comentários a estes Manuais