Simrad HS50 Heading Sensor 2 20221081 / F High-precision heading is derived from the fixed-distance dual GPS antenna arrangement in the Sensor unit,

Página 3 - HS50 Heading Sensor

INTRODUCTION 20221081 / F 3 1.2 About this manual This manual is intended as a reference guide for operating, installing and maintaining the HS50 He

Página 4 - Document history

Simrad HS50 Heading Sensor 4 20221081 / F Abbreviations and acronyms CEP Circular Error Probability COG Course Over Ground DGPS Differential GPS DU H

Página 5 - Contents

TECHNICAL SPECIFICATIONS 20221081 / F 5 2. TECHNICAL SPECIFICATIONS 2.1 Health, environment and safety Operation or troubleshooting of HS50 equipme

Página 6

Simrad HS50 Heading Sensor 6 20221081 / F 2.4 Performance data Heading accuracy, static:...0.3° RMS Head

Página 7 - 20221081 / F v

TECHNICAL SPECIFICATIONS 20221081 / F 7 Processing unit Width: ...287 mm (11.3 in.) Heigh

Página 8

Simrad HS50 Heading Sensor 8 20221081 / F Processing unit Enclosure material: ...Anodized aluminum Enclosure prot

Página 9 - 1. INTRODUCTION

INSTALLATION 20221081 / F 9 3. INSTALLATION 3.1 General The following parts are supplied with a standard HS50 system: − Sensor unit with 1 meter c

Página 10 - 20221081 / F

Simrad HS50 Heading Sensor 10 20221081 / F 3.4 Sensor unit Location of the unit The Sensor unit is the most important part of the HS50 system, and g

Página 11 - 1.2 About this manual

INSTALLATION 20221081 / F 11 Mechanical installation The Sensor unit may be mounted in the mast or directly on the deck. The dimensional drawing for

Página 12 - Abbreviations and acronyms

Note! Simrad AS makes every effort to ensure that the information contained within this document is correct. However, our equipment is continuously be

Página 13 - 2. TECHNICAL SPECIFICATIONS

Simrad HS50 Heading Sensor 12 20221081 / F Bracket mounting (option) An optional mounting bracket (part no. 20213039) can be delivered from Simrad by

Página 14 - 2.5 Physical dimensions

INSTALLATION 20221081 / F 13 Pedestal mounting (option) An optional mounting pedestal (part no. 20213021) can be delivered from Simrad by request. Th

Página 15 - 2.6 Power

Simrad HS50 Heading Sensor 14 20221081 / F If the Sensor unit connector needs to be reconnected to the cable, the wiring for the cable within the Sen

Página 16 - 2.8 Cable

INSTALLATION 20221081 / F 15 Panel mounting Two mounting methods may be used when panel mounting the HS50 Display unit. A drilling template, part no.

Página 17 - 3. INSTALLATION

Simrad HS50 Heading Sensor 16 20221081 / F Bracket mounting (option) An optional bracket, part no. 22084941, may be ordered from Simrad. Note! When

Página 18 - 3.4 Sensor unit

INSTALLATION 20221081 / F 17 Display unit cable The 15 m cable to the Processing unit has connector only at the Display unit end. Optional extensions

Página 19 - Mechanical installation

Simrad HS50 Heading Sensor 18 20221081 / F 3.6 Processing unit The Processing unit is not waterproof and should be mounted vertically in a dry place

Página 20

INSTALLATION 20221081 / F 19 Cable connections Proceed as follows to connect the cables to the Processing unit: 1 Remove the bottom cover (terminal

Página 21 - Pipe clamps

Simrad HS50 Heading Sensor 20 20221081 / F The pinout for each terminal is as follows: ALARM GREENPOWC YELLOWP200 DISPLAYGND GREYUNITPWR PINKBUS+ WH

Página 22 - 3.5 Display unit

INSTALLATION 20221081 / F 21 Connecting to Simrad equipment The figures on the following pages show how HS50 is connected to Simrad equipment. All eq

Página 23 - Panel mounting

INSTRUCTION MANUAL 20221081 / F i Instruction Manual HS50 Heading Sensor This manual is intended as a reference guide for installing, operating and m

Página 24 - Bracket mounting (option)

Simrad HS50 Heading Sensor 22 20221081 / F J50/J300X Junction unit PROCESSING UNITHS50JUNCTIONJ50 / J300XUNITRX2+RX2-422- OUT422+ OUT232 OUTGNDorP204

Página 25 - Display unit cable

INSTALLATION 20221081 / F 23 RGC12 Gyro Compass PROCESSING UNITHS50P203P204orP202,232 OUT422+ OUT422- OUTGNDRGC12TERMINAL BOARDGRXHGRXLTB7 Simrad RA4

Página 26 - 3.6 Processing unit

Simrad HS50 Heading Sensor 24 20221081 / F 3.7 Software setup procedure This chapter describes a number of installation settings that must be perfor

Página 27 - Cable connections

INSTALLATION 20221081 / F 25 Example: The following example shows how to change the ROT Max value in the Display adjustment submenu using the keys an

Página 28 - 20 20221081 / F

Simrad HS50 Heading Sensor 26 20221081 / F Differential corrections The signal cable with the differential corrections is connected to the terminal b

Página 29 - CONTROL UNIT

INSTALLATION 20221081 / F 27 Data output The Processing unit has two individually configurable output serial lines. On output line Data output 1 two

Página 30 - J50 / J300X

Simrad HS50 Heading Sensor 28 20221081 / F Ethernet The Processing unit can output data on Ethernet from terminal J60. In the Ethernet submenu the IP

Página 31 - TRUE to MAGNETIC

INSTALLATION 20221081 / F 29 Height aiding For operations with weak satellite geometry the position output can be made more accurate by using height

Página 32 - SETUP button for 5 seconds

Simrad HS50 Heading Sensor 30 20221081 / F Expert setup By pressing the SETUP button twice and then holding this button for 5 seconds, an Expert Setu

Página 33 - Display Adjustments

INSTALLATION 20221081 / F 31 Run mode: Used for switching the HS50 between NORMAL and DEMO mode. DEMO mode is used for simulating input data to the

Página 34 - Differential corrections

Simrad HS50 Heading Sensor ii 20221081 / F Document revisions Rev Date Written by Checked by Approved by A 12.06.02 FOS/ B 26.09.02 C 06

Página 35 - Data output

Simrad HS50 Heading Sensor 32 20221081 / F The average value for observations from each of the two different systems should then be used, and the off

Página 36 - General

OPERATING INSTRUCTIONS 20221081 / F 33 4. OPERATING INSTRUCTIONS 4.1 Overview The Display unit is used for setup and operation of the HS50. Each of

Página 37 - 20221081 / F 29

Simrad HS50 Heading Sensor 34 20221081 / F FUNCTION REF. PAGE The rotary knob is used for entering values in SETUP submenus, and for adjusting the

Página 38 - Expert setup

OPERATING INSTRUCTIONS 20221081 / F 35 • POS-Q. The quality of the position measurements. Two black bar graphs indicate normal accuracy, one black a

Página 39 - 20221081 / F 31

Simrad HS50 Heading Sensor 36 20221081 / F GPS heading, the heading output is determined from the inertial element. The data quality status informati

Página 40

OPERATING INSTRUCTIONS 20221081 / F 37 Third NAV2/POS display: the Satellite skyplot. This display shows satellites in sight by the Sensor unit, and

Página 41 - 4. OPERATING INSTRUCTIONS

Simrad HS50 Heading Sensor 38 20221081 / F In this display, a number of additional information on the heading solution is presented. This informati

Página 42 - 4.3 Performance monitoring

OPERATING INSTRUCTIONS 20221081 / F 39 Number of satellites used in the GPS position solution and the number of satellites tracked by GPS antenna no

Página 43 - ROT 0.6 º/s

Simrad HS50 Heading Sensor 40 20221081 / F Invalid Position alarm Activated if the system has been unable to determine position the last two seconds,

Página 44 - Navigation/POS display

OPERATING INSTRUCTIONS 20221081 / F 41 4.5 Operation The HS50 will normally output signals on the serial lines without any involvement from the user

Página 45 - Info displays

INSTRUCTION MANUAL 20221081 / F iii Contents 1. INTRODUCTION ...1 1.1 HS50 System comp

Página 46

Simrad HS50 Heading Sensor 42 20221081 / F THIS PAGE INTENTIALLY LEFT BLANK

Página 47 - 4.4 Alarms

MAINTENANCE 20221081 / F 43 5. MAINTENANCE 5.1 General Service on the HS50 hardware in the field can consist of: • Replacing damaged cables • Rep

Página 48 - Invalid Heading alarm

Simrad HS50 Heading Sensor 44 20221081 / F Re-calibration of the Sensor unit The direction of the Sensor unit relative to the vessel's heading h

Página 49 - 4.5 Operation

MAINTENANCE 20221081 / F 45 5.3 Repairs and modifications Repair of the HS50 units is limited to replacement of damaged cables, Sensor unit, Process

Página 50 - 42 20221081 / F

Simrad HS50 Heading Sensor 46 20221081 / F No response In normal operation it takes about one minute from the Display unit is powered on until inform

Página 51 - 5. MAINTENANCE

MAINTENANCE 20221081 / F 47 No Differential corrections The possible reason for a white box for differential correction indication (DIF) could be one

Página 52 - Software upgrades

Simrad HS50 Heading Sensor 48 20221081 / F Reduced heading indication The reason for reduced heading performance could be one of the following: • Th

Página 53 - 5.4 Troubleshooting

FIGURES AND DRAWINGS 20221081 / F 49 6. FIGURES AND DRAWINGS This section contains outline drawings showing the mechanical dimensions of the differe

Página 54 - No valid data

Simrad HS50 Heading Sensor 50 20221081 / F 6.1 Sensor unit, dimensions Approved :Checked :Subtitle:Title :Issued :Drawing no:Xref file : Project

Página 55 - Invalid Heading

FIGURES AND DRAWINGS 20221081 / F 51 6.2 Sensor unit bracket, dimensions Approved :Checked :Subtitle:Title :Issued :Drawing no:Xref file : Proje

Página 56 - Simulated data

Simrad HS50 Heading Sensor iv 20221081 / F Cable wiring... 13 Waterproofing the conne

Página 57 - 6. FIGURES AND DRAWINGS

Simrad HS50 Heading Sensor 52 20221081 / F 6.3 Sensor unit pedestal, dimensions Approved :Checked :Subtitle:Title :Issued :Drawing no:Xref file

Página 58 - 6.1 Sensor unit, dimensions

FIGURES AND DRAWINGS 20221081 / F 53 6.4 Processing unit, dimensions

Página 59 - FIGURES AND DRAWINGS

Simrad HS50 Heading Sensor 54 20221081 / F 6.5 Display unit, dimensions Note! Mounting bracket is optional

Página 60 - 52 20221081 / F

PARTS LIST 20221081 / F 55 7. PARTS LIST 7.1 Standard delivery The standard HS50 consists of: Part no. No. Description 20212858 1 HS50 Sensor

Página 61

INSTRUCTION MANUAL 20221081 / F v Processing unit ... 44 Display unit ...

Página 62

Simrad HS50 Heading Sensor vi 20221081 / F THIS PAGE INTENTIALLY LEFT BLANK

Página 63 - 7. PARTS LIST

INTRODUCTION 20221081 / F 1 1. INTRODUCTION 1.1 HS50 System components Simrad HS50 is a GPS compass that provides true heading output with position

Comentários a estes Manuais

Sem comentários